Ordering is Easy as 1-2-3

1. COLLECT IN OUR cup Or VIAL

2 mL Barcode Specimen Tube

Candidiasis Panel, Vaginitis Panel, STI Panel, Lesion Panel, Wound Panel,  GBS, C. diff, Respiratory Pathogens Panel (RPP)*

5 mL Barcode Specimen Tube

Wound Panel, Respiratory Pathogens Panel (RPP)*

Specimen Cup

UTI Panel, C.diff, GI Panel

Specimen Collection
  1. Open the individually wrapped collection swab wrapper by peeling open the top of the wrapper.
  2. Remove the swab, taking care not to touch the tip or lay it down.
    Note: If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new swab.
  3. Continue holding the swab in the same hand. With your other hand, unscrew the cap from the Swab Transport Media tube.
    Note: Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Swab Transport Media tube.
  4. Immediately place the swab into the Swab Transport Media tube.
  5. Identify the scoreline on the collection swab shaft. Carefully break the swab shaft against the side of the tube at the scoreline to avoid splashing the contents. Discard the top portion of the swab shaft.
  6. Re-cap the Swab Transport Media tube and tighten the cap securely.
  7. Invert the tube 3-4 times to ensure proper preservation of specimen.
  8. Label the transport tube with the specimen identification information as required.
Order MORe kits & Supplies

2. Place the order

Our lab offers a streamlined process for submitting test orders through our secure online portal. Physicians or clinical staff can easily enter orders digitally, then use our pre-barcoded vials to label and collect samples. Once the vial is scanned, the order is automatically linked to the correct patient and test. This system reduces errors and ensures proper tracking throughout the entire workflow. Results are then delivered directly into the physician’s EHR system via seamless integration, enabling faster, more accurate diagnoses and improving patient care through real-time data access.

OPTION 1:
Labtest.bio is integrated with Athena Health. If your facility is using Athena, you can place the order easily through you Athena interface.
  1. Select patient to place the lab order
  2. Search and select the lab facility “Labtest.bio – Georgetown”
  3. Search order code and select the diagnostics panel to order
    • A00005 – Candidiasis Panel
    • A00006 – Vaginitis Panel
    • A00008 – Sexually Transmitted Infection (STI Panel)
    • A00022 – Lesion
    • A00018 – Urinary Tract Infection (UTI)
    • A00002 – Respiratory Pathogens panel (RPP – Limited)
    • A00013 – Respiratory Pathogens panel (RPP – Basic)
    • A00002 – Respiratory Pathogens panel (RPP – Extended)
    • A00014 – Respiratory Pathogens panel
    • A00023 – GBS
    • A00004 – Clostridium difficile with toxins
    • A00020 – Wound Panel
  4. Answer the AOE questions if it’s applicable. – Scan or Enter the ID on the tube in order form (recommended)
  5. Sign and submit the order
OPTION 2:
Labtest.bio provides a physician portal for placing lab order and reviewing results.
If you haven’t signed up yet, use the button link below to signed up account.
If you already have an account with us, click the button below to access our portal.
Following the steps in the instruction to place a lab order.
If you have any question or need helps, please feel free to contact us:

Click button below to use our portal

Sign in the portal to place you order and review the results.

3. Put the sample in the Biohazard bag, then place in the dropbox

As part of our commitment to enhancing clinical efficiency, our lab offers no-charge integration between our Laboratory Information Management System (LIMS) and the physician’s Electronic Health Record (EHR) system. This program is designed to eliminate manual data entry, reduce administrative burden, and accelerate the delivery of test results. By providing this integration at no cost, we ensure that practices of all sizes can benefit from seamless, secure, and automated data exchange—helping clinicians make timely decisions with the most accurate, up-to-date information right within their existing workflow.

lab worker with swab sample for covid-19 test

Scan QR Code FOR UPS PICKUP,
or click below to schedule

Call us at 800-522-7740
Or, Chat with us online

Photo of doctors review test results
Specimen Collection
  • Anal (ANAL): Place the swab onto the affected area of the anus and rotate the swab for 10-30 seconds.
  • Anterior Nasal (AN): Tilt the patient’s head back and insert the swab into the affected patient’s nostril about 2 cm. Rotate the swab for 10-30 seconds. Repeat with the same swab in the other nostril.
  • Endocervical (EC): Insert the collection swab into the endocervical canal and rotate the swab on the cervix for 10-30 seconds.
  • Nail (NAIL): Place the swab onto the affected area of the nail and rotate the swab for 10-30 seconds.
  • Oral (ORL): Instruct the patient to open mouth widely, positioning the tongue toward the bottom of their mouth. Swab affected areas of the cheeks, tongue, gums, lips, and/or palate for 10-30 seconds.
  • Oropharyngeal (OPH): Instruct the patient to open mouth widely, positioning the tongue toward the bottom of their mouth. Swab areas of the pharynx (tonsil, posterior wall, uvula) for 10-30 seconds.
  • Penile (PEN): Place the swab onto the affected area of the penis and rotate the swab for 10-30 seconds.
  • Rectal (REC): Place the swab into the patient’s rectum approximately 5 cm past the anus. Rotate the swab for 10-30 seconds. Ensure the swab touches the rectal walls so that moisture is absorbed by the swab.
  • Urethral (URE): Place the swab into the patient’s urethra approximately 3 cm. Rotate the swab for 10-30 seconds. Ensure the swab touches the walls of the urethra so that moisture is absorbed by the swab.
  • Vaginal (VAG): Place the swab into the patient’s vagina approximately 5 cm. Rotate the swab for 10-30 seconds. Ensure the swab touches the walls of the vaginal cavity so that moisture is absorbed by the swab.
  • Vulval (VUL): Place the swab onto the affected area of the vulva and rotate the swab for 10-30 seconds.
  • Wound (WND): Place the swab onto the wound and rotate the swab for 10-30 seconds. Withdraw the swab carefully to avoid touching any other site outside of the affected area/lesion.